Company | Deck Type | Membrane Mfr. | System | INC. | Surfacing Coating | U.L.Class |
---|---|---|---|---|---|---|
All Weather Rfg Systems Ft. Worth, TX. | NC | All Weather Mod. Bit. | Insulation: Perlite, GF, WF Any thicknessBase Sheet: Type G-2 Membrane: All Weather Mod. Bit. Rfg. Membrane | 1/4" | #97 (1 - 1/2gal/sq) | A |
Apache products Meridian, MS. | NC | Celotex | Insulation: (optional) PYROX, Tapered PYROX, Isofoil, or Millox Membrane: Celotex APP 4/S, 4/M White or Black Stallion SBS 170, 250 | 1" | #97 or #97AF (1- 1/2gal/sq) | A |
Apache products Meridian, MS. | C-15/32 | Celotex | Barrier Board: Water Resist. 1/2" GYP. Insulation: (optional) PYROX, Tapered PYROX, Isofoil, or Millox Base Sheet: Type G-2 Membrane: Celotex APP 4/S, 4/M White or Black Stallion SBS 170, 250 | 1" | #97 or #97AF (1- 1/2gal/sq) | A |
Amerival Corp. Houston, TX. | NC | Amerival | Insulation: (optional) Base Sheet: Yes Membrane: Amerival APP3, APP4, APP4.5, APP5 | 1/2" | #97 (1-2gal/sq) | A |
Amerival Corp. Houston, TX. | NC | Amerival | Insulation: (optional) Base Sheet: Yes Membrane: Sealflex | 1/4" | #97 (1-2gal/sq) | A |
Amerival Corp. Houston, TX. | C-15/32 | Amerival | Insulation: (optional) Insulation: (optional) Insulation: (optional) APP4.5-FR, APP5-FR | 1/2" | #97 (1-2gal/sq) | A |
Amerival Corp. Houston, TX. | C-15/32 | Amerival | Insulation: (optional) Base Sheet: Yes Membrane: APP3-FR, APP4-FR, APP4.5-FR, APP5-FR | 1/2" | #97 (1-2gal/sq) | B |
Atlas Energy Products Atlanta, GA. | NC | Nord Bitumi | Insulation: (optional) Base Sheet: G2 Membrane: NP-5B, 4B, 4M, EM-4000, NORD 200, NORDFLEX S, ULTRA S, NORDFLEX 170, NORDFLEX ULTRA M | 1" | #97 or #97AF (1-2gal/sq) | A |
Atlas Energy Products Atlanta, GA. | C-15/32 | Nord Bitumi | Barrier Board: Gyp. Insulation: (optional) Base Sheet: G2 Membrane: NP-5B, 4B, 4M, EM-4000, NORD 200, NORDFLEX S, NORDFLEX M NORDFLEX 170, NORDFLEX ULTRA M |
1" | #97 or #97AF (1-2gal/sq) | A |
Atlas Energy Products Atlanta, GA. | C-15/32 | Nord Bitumi | Insulation: AC-Foam I or II Base Sheet: GAF, OCF, MAN., Tamko Membrane: NP-5B, 4B, 4M, EM-4000, NORD 200, NORDFLEX S, ULTRA S NORDFLEX 170, NORDFLEX ULTRA M |
1/2" | #97 or #97AF (1-2gal/sq) | A |
Atlas Energy Products Atlanta, GA. | C-15/32 | Nord Bitumi | Insulation: AC-Foam I or II Cover Board: W.F., F.G., Perlite Base Sheet: GAF, OCF, MAN., Tamko Membrane: NP-5B, 4B, 4M, EM-4000, NORD 200, NORDFLEX S, ULTRA S NORDFLEX 170, NORDFLEX ULTRA M | 1/2" | #97 or #97AF (1-2gal/sq) | A |
Atlas Energy Products Atlanta, GA. | C-15/32 | Nord Bitumi | Insulation: AC-Foam I or II Base Sheet: GAF, OCF, MAN., Tamko Membrane: NP-5B, 4B, 4M, EM-4000, NORD 200, NORDFLEX S, ULTRA S NORDFLEX 170, NORDFLEX ULTRA M NORDFLEX 170, NORDFLEX ULTRA M | 1/2" | #97 or #97AF (1-2gal/sq) | A |
Atlas Energy Products Atlanta, GA. | C-15/32 | Nord Bitumi | Insulation: AC-Foam II Base Sheet: GAF, OCF, MAN., Tamko Membrane: NP-4B, 4M, EM-4000, NORD 200, NORDFLEX S,M, ULTRA S,M | 1/2" | #97 or #97AF (1-2gal/sq) | B |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: APM-4.5T, APS-4T, ISA-4T | 1-1/2 | #97 or #97AF (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: SPS-3H, SPM-3.5H, SFM-3.5H, SFM-3H | 3/4" | #97 or #97AF (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: SPM-4.5T | 3/4" | #97 or #97AF (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: None Base Sheet: 2 plies Type G-2 Membrane: APM-4.5T, APS-4T, ISA-4T SPM-4.5T | 1/2" | #97 or #97AF (1-2gal/sq) | A |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: None Base Sheet: 3 plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T | 1" | #97 or #97AF (1-2gal/sq) | A |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: Various Base Sheet: 1 or more plies Type G-2 Membrane: SPS-3H, SPM-3.5H, SFM-3.5H, SFM-3H | 3/4" | #97 or #97AF | A |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: None Membrane: SPS-3H, SPM-3.5H, SFM-3.5H,SFM-3H | 1/2" | #97 or #97AF (1-2gal/sq) | A |
BITEC Inc Morrilton AR. | C-15/32 | BITEC | Insulation: (Optional) Base Sheet: 3 plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T | 1/2" | #97 or #97AF (1-2gal/sq) | A |
BITEC Inc Morrilton AR. | C-15/32 | BITEC | Insulation: Various/2 or more layers Base Sheet: 1 or more plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H | 1/4" | #97 or #97AF (1-2gal/sq) | A |
BITEC Inc Morrilton AR. | NC | BITEC | Insulation: Insulating Concrete Base Sheet: 1 or more plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T | 1" | #97 or #97AF (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | C-15/32 | BITEC | Insulation: Any UL approved insulation Base Sheet: Type G-2, Hot Mopped Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T | 1" | #97 or #97AF (1-2gal/sq) | A |
BITEC Inc Morrilton AR. | C-15/32 | BITEC | Insulation: Various/2 min layers 3" min Base Sheet: Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H | 1/2" | #97 (1-2gal/sq) | B |
BITEC Inc Morrilton AR. | C-15/32 | BITEC | Insulation: NONE Base Sheet: 2 plies Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H | 1/2 | #97 (1-1/2gal/sq) | B |
BITEC Inc Morrilton AR. | NCRC | BITEC | Existing: BUR, A,B or C, S or G Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H | 1/2" | #97 or #97AF (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | C-15/32 RC | BITEC | Existing: BUR, A,B or C, S or G(remo) Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H, SPM-3.5H, SPS-3H | 1/2" | #97 (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | NCRC | BITEC | Existing:BUR,A,B or C, Grav part/remo Base Sheet: Type G-2 Membrane: APS-4T, ISA-4T | 1/2" | #97 (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | Struct. Cement- FiberRC | BITEC | Existing: BUR, A,B or C, S or G Base Sheet: Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T, ISA-4T, SPM-4.5T, SFM-3H, SPM-3.5H | 1/2 | #97 (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | NCRC | BITEC | Existing: BUR, A,B or C, S or G Insulation: EPS/Overlaid WF or Perlite Base Sheet: Type G-2 Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SPM-3.5H | 1/2" | #97 (1-1/2gal/sq) | A |
BITEC Inc Morrilton AR. | NCRC | BITEC | Existing: BUR, A,B or C, S or G Base Sheet: (Optional) Membrane: APM-4T, APM-4.5T, APS-4T,ISA-4T, SPM-4.5T, SFM-3H, SFM-3.5H,SPM-3.5H, SPS-3H | 1/2" | #97 (1-1/2gal/sq) | B |
BITEC RFG. of Canada, Inc. Quebec,Canada | NC | BITEC | Insulation: Perlite, GlassFiber, W.F. Base Sheet: Type G-2 Membrane: Elastoplan 180 G/P, 180 G/S | 1-1/2" | #97 (1-1/2gal/sq) | A |
BITEC RFG. of Canada, Inc. Quebec,Canada | NC | BITEC | Insulation: Perlite, GlassFiber, W.F. Base Sheet: Type G-2 Membrane: Elastoplan 250 G/P, 250 G/S | 3/4" | #97 (1-1/2gal/sq) | A |
Bitufa BV 7336 AR Apeldoorn Netherlands | NC | Bitufa BV | Insulation: Perlite, GlassFiber, W.F., ISO Base Sheet: (Optional) Unibase Membrane: Flexoper N5, S5, Flexobit | 1/2" | #97 (1-1/2gal/sq) | A |
Bitufa BV 7336 AR Apeldoorn Netherlands | NC | Bitufa BV | Insulation: Perlite, GlassFiber, W.F., ISO Base Sheet: (Optional) Unibase Membrane: Flexoper MF5N, MF5S |
1" | #97 (1-1/2gal/sq) | A |
Bitufa BV 7336 AR Apeldoorn Netherlands | NC | Bitufa BV | Insulation: Perlite, GlassFiber, W.F., ISO Base Sheet: Type G-1 or G-2 Membrane: Flexoper N5, S5, Flexobit | 1/2" | #97 (1-1/2gal/sq) | A |
Bitufa BV 7336 AR Apeldoorn Netherlands | NC | Bitufa BV | Insulation: Perlite, GlassFiber, W.F., ISO Base Sheet: Type G-1 or G-2 Membrane: Flexoper MF5N, MF5S | 1" | #97 (1-1/2gal/sq) | A |
BMCA Insulation Products, Inc. Ontario, CA. | NC M & R | Premaflex | Existing Roof System: A, B or C (gravel may be removed) Base Sheet: Type G-3 invverted Membrane: Permalite Permaflex RS, Peragrip RS | 1" | #169 (Optional) (1 gal/sq) | A |
CELOTEX CORP. Tampa, FL. | NC | CELOTEX | Insulation: Perlite, GlassFiber, W.F. Base Sheet: Type G-2 Membrane: APP 4/S, APP TORCHDOWN | 2" | #97 or #97AF(1-1/2gal/sq) | A |
CELOTEX CORP. Tampa, FL. | NC | CELOTEX | Base Sheet: N/A Membrane: APP 4/S, APP TORCHDOWN, APP- White Stallion, APP Black Stallion,SBS170, SBS250, SBS Smooth Cap Sheet | 1" | #97 or #97AF(1-1/2gal/sq) | A |
CELOTEX CORP. Tampa, FL. | C-15/32 | CELOTEX | Barrier Board: GypsumInsulation: OptionalBase Sheet: Type G-2, or APP BaseMembrane: APP 4/S, APP TORCHDOWN, APP-White Stallion, APP4/M Black Stallion,SBS170, SBS250, SBS Smooth Cap Sheet | 1" | #97 or #97AF(1-1/2gal/sq) | A |
CELOTEX CORP. Tampa, FL. | NC | CELOTEX | Base Sheet: OptionalMembrane: APP 4/S, APP TORCHDOWN, APP-White Stallion, APP Black Stallion,SBS170, SBS250, SBS Smooth Cap Sheet | 1" | #97 or #97AF(1-1/2gal/sq) | A |
CELOTEX CORP. Tampa, FL. | C-15/32 | CELOTEX | Base Sheet: Type G-2Membrane: APP 4/S, APP TORCHDOWN, APP-White Stallion, APP Black Stallion,SBS170, SBS250, SBS Smooth Cap Sheet | 1/2" | #97 or #97AF(2 gal/sq) | A |
CELOTEX CORP. Tampa, FL. | C-15/32 | CELOTEX | Insulation: Glass FiberBase Sheet: Type G-2, or APP BaseMembrane: APP 4/S, APP TORCHDOWN, APP-White Stallion, APP4/M Black Stallion,SBS170, SBS250, SBS Smooth Cap Sheet | 1/4" | #97 or #97AF (2 gal/sq) | A |
CELOTEX CORP. Tampa, FL. | C-15/32 | CELOTEX | Base Sheet: Type G-2, or APP Base Membrane: APP 4/S, APP TORCHDOWN, APP- White Stallion, APP4/M Black Stallion,SBS170, SBS250, SBS Smooth Cap Sheet | 1/2" | #97 or #97AF (1-1/2gal/sq) | B |
CELOTEX CORP. Tampa, FL. | C-15/32 | CELOTEX | Insulation: Polyisocyanurate Base Sheet: Type G-2, or APP Base Membrane: APP 4/S, APP TORCHDOWN, APP- White Stallion, APP4/M Black Stallion,SBS170, SBS250, SBS Smooth Cap Sheet | 1/2 | #97 or #97AF (1-1/2gal/sq) | B |
CELOTEX CORP. Tampa, FL. | C-15/32 | CELOTEX | Insulation: Polyisocyanurate Insulation: WF, Glass Fiber, Perlite Membrane: APP 4/S, APP TORCHDOWN, APP- White Stallion, APP4/M Black Stallion, SBS170, SBS250, SBS Smooth Cap Sheet | 1" | #97 or #97AF (1-1/2gal/sq) | B |
CELOTEX CORP. Tampa, FL. | C-15/32 M & R | CELOTEX | Existing System: Class A,B,C (gravel may be removed) Insulation: Optional Membrane: APP 4/S, APP TORCHDOWN, APP- White Stallion, APP4/M Black Stallion, SBS170, SBS250, SBS Smooth Cap Sheet | 1/2" | #97 or #97AF (1-1/2gal/sq) | A |
Consolidated Coatings, Corp. Cleveland, OH. | NC | Unknown | Insulation: GF, Perlite, WF Base Sheet: Type G-2, Mechanically Fastened Membrane: CONSO-GARD IIIB | 1/4" | #97 (2 gal/sq) | A |
Continental Materials, Inc Glenside, PA. | C-15/32 M & R | Republic | Existing System: Class A,B,C (gravel may be removed) Insulation: WF mech. attached Base Sheet: Type G-2 Membrane: Republic Torch-Guard APP- Smooth, Torch-Guard APP Slated | 1/2 | #97 (1-1/2gal/sq) | A |
Continental Materials, Inc Glenside, PA. | C-15/32 M & R | Republic | Existing System: Class A,B, Cap Sheet: UL Type G3 Mech. Attached Membrane: Republic Torch-Guard APP- Smooth | 1/2" | #97 (1-1/2gal/sq) | A |
Continental Materials, Inc Glenside, PA. | NC | Republic | Insulation: Various Base Sheet: Type G-2 Membrane: Republic Flex-Guard SBS- Torch Applied | 1/2" | #97 (1-1/2gal/sq) | A |
Continental Materials, Inc Glenside, PA. | NC | Republic | Insulation: Various Base Sheet: Type G-2 Membrane: Republic Torch-Guard APP- Slated, Torch-Guard APP Smooth | 1/4" | #97 (1-1/2gal/sq) | A |
Continental Materials, Inc Glenside, PA. | C-15/32 | Republic | Insulation: Various Base Sheet: Type G-2 Membrane: Republic Flex-Guard SBS- Slated | 1/2" | #97 (1-1/2gal/sq) | A |
Danosa CaribbeanInc. San Juan, PR. | NC M & R | Danosa | Existing Roof System: A,B,C covered withMembrane: Glasdan R-36, S, S-2, or RM,Esterdan R-36,S, RM, Danoplax Mod.Glasdan R-36Mod. Esterdan R-36 or RM | 2" | #97(2gal/sq) | A |
Danosa CaribbeanInc. San Juan, PR. | NC | Danosa | Insulation: (Optional) GF,Perlite 1" Max.Membrane: 2 layers Mod. Glasdan R-36 or 2 layersMod. Esterdan R-36, or 1 layer Mod. Glasdan R-36covered w/ Mod.Glasdan RM-4, 1 layer Mod. EsterdanR-36 covered w/ Mod. Esterdan RM-4, 1 layer Mod.Glasdan RM-5, or 1 layer Mod. Esterdan RM-5 | 1/4" | #97(2gal/sq) | A |
Danosa CaribbeanInc. San Juan, PR. | NC | Danosa | Note: Deck must be one of the following:A.) Monolithic poured cementitious deck,B.) Steel covered w/ GYP. or Perlite Board, C.) Structual w/ all joints caulked, D.) Metal deck covered Cellular , GYP., Vermiculite, orPerlite concrete | 1/4" | #97 (2gal/sq) | A |
Design 8000Intercon BldgsN. Burnswick,NJ | NC | Design8000 | Insulation: Various Base Sheet: Type G-2Membrane: Poly 4/200 (Mod. Bit.) | 1 1/2" | #97(1-1/2gal/sq) | A |
Design 8000Intercon BldgsN. | NC | Design8000 | Insulation: VariousBase Sheet: Type G-2 Membrane: Poly 4/200 MS (Mod. Bit.) | 3/4" | #97 (1-1/2gal/sq) | A |
Design 8000Intercon BldgsN. | NC | Design8000 | Base Sheet: 2 Layers Type G-2Membrane: Poly 4/200 (Mod. Bit.) | 1/2" | #97 (1-2gal/sq) | A |
Design 8000Intercon BldgsN. | NC | Design8000 | Base Sheet: 3 Layers Type G-2Membrane: Poly 4/200 MS (Mod. Bit.) | 1/2" | #97 (1-2gal/sq) | A |
Design 8000Intercon BldgsN. | NC | Design8000 | Insulation: Various Base Sheet: Type G-2Membrane: Poly 4/200, 4/200M(Mod.Bit.) | 1" | #97(1-2gal/sq) | A |
Design 8000Intercon BldgsN. | NC | Design8000 | Insulation: VariousBase Sheet: Type G-2Membrane: Poly 4/200 MS (Mod. Bit.) | 3/4" | #97(1-2gal/sq) | A |
Design 8000Intercon BldgsN. | C-15/32 | Design8000 | Insulation: Various Base Sheet: Type G-2Membrane: Poly 4/200, 4/200M, 4/200MS | 1/2" | #97(1-2gal/sq) | A |
Design 8000Intercon BldgsN. | C-15/32 | Design8000 | Insulation: Various Base Sheet: Type G-2Membrane: Poly 4/200, 4/200M, 4/200MS | 1/4" | #97(1-2gal/sq) | A |
Design 8000Intercon BldgsN. | NC | Design8000 | Insulation: Concrete typeBase Sheet: Type G-2 mech. attachedMembrane: Poly 4/200, 4/200M | 1" | #97(1-2gal/sq) | A |
Design 8000Intercon BldgsN. | C-15/32 | Design8000 | Insulation: Various Base Sheet: Type G-2Membrane: Poly 4/200, 4/200M | 1/2" | #97(1-2gal/sq) | B |
Design 8000Intercon BldgsN. | Design8000 | Base Sheet: 2 layers Type G-2Membrane: Poly 4/200M, 4/200MS | 1/2" | #97 (1-2gal/sq) | B | |
Dibiten USA S. Gate, CA. | NC | Dibiten | Base Sheet: Type G-2Membrane: 4.0 Poly, 4.5 Poly, 5.0 Poly | 1/2" | #97(1gal/sq) | A |
Dibiten USA S. Gate, CA. | NC | Dibiten | Insulation: VariousBase Sheet: Type G-2Membrane: Dibiflex S, Supra S, or 170 | 1/4" | #97 or #97AF(1-2gal/sq) | A |
Dibiten USA S. Gate, CA. | C-15/32 | Dibiten | Base Sheet: 2 plies Type G-2Membrane: 4.0 Poly, 4.5 Poly, 5.0 Poly | #97 (1gal/sq) | B | |
DWI DermabitWater. Indust.Saudi Arabia | NC | Dermabit | Insulation: Various Base Sheet: Type G-2Membrane: Dermabit 3050 APP SmoothElasphalt 4170 SBS, Adesobit 2050 P&S | 1/2" | #97 (1-1/2gal/sq) | A |
DWI DermabitWater. Indust.Saudi Arabia | NC | Dermabit | Insulation: Various Base Sheet: Type G-2Membrane: Dermabit 4170 APP SlatedDermabit 4170 APP Smooth | 1/4" | #97 (1-1/2gal/sq) | A |
DWI DermabitWater. Indust.Saudi Arabia | C-15/32 | Dermabit | Insulation: VariousBase Sheet: Type G-2Membrane: Dermabit 3050 APP SmoothElasphalt 4170 SBS, Slated | 1/2" | #97 (1-1/2gal/sq) | A |
DWI DermabitWater. Indust.Saudi Arabia | C-15/32 | Dermabit | Existing: Class A,B gra.may be removedInsulation: WFBase Sheet: Type G-2Membrane: Dermabit 4170 APP Smooth,4170 APP Slated, 3050 APP Smooth,Elasphalt 4170 SBS Slated, Elasphalt-2050 Peel & Stick | 1/2" | #97 (1-1/2gal/sq) | A |
DWI DermabitWater. Indust.Saudi Arabia | C-15/32 | Dermabit | Existing: Class A,B gra.may be removedCap Sheet: UL classified Type G-3Membrane: Dermabit 4170 APP Smooth, | 1/2" | #97 (1-1/2gal/sq) | A |
Firestone Bldg.Products Co.Carmel, IN. | NCM & R | Firestone | Existing System: Class A,B,C(gravel may be removed)Base Sheet: Type G-1, G-2, or G-3Membrane: Firestone APP 160, 170 orMonoply Plus | #97 or #97AF(1-1/2gal/sq)#169(1gal/sq) | A | |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32M & R | Firestone | Existing System: Class A Ply Sheet: OFC #11 or 28 Base or plyMembrane: Firestone APP 160, 170 orMonoply Plus | #97 or #97AF(1-1/2gal/sq) | A | |
Firestone Bldg.Products Co.Carmel, IN. | NCM & R | Firestone | Existing System: Class A,B,C(gravel may be removed)Insulation: OptionalBase Sheet: Type G-1, G-2, or G-3Membrane: Firestone APP 160, 170 or Monoply Plus | #97 or #97AF(1-1/2gal/sq)#169(1gal/sq) | A | |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Existing System: Class A,B,C Insulation: Optional Base Sheet: 2 layers OFC/schuller #28 Membrane: Firestone APP 160, 170 or Monoply Plus |
1/2" | #97 or #97AF (1-1/2gal/sq) |
B |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Base Sheet: Optional Membrane: Firestone APP 160, 170 orMonoply Plus |
1/2" | #97 or #97AF (1gal/sq) |
B |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Existing System: Class A,B,C
Insulation: 1 Layer ISO or Glass fiber |
1/2" | #97 or #97AF
(1-1/2gal/sq) |
B |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Existing System: Class C Membrane: Firestone APP 160, 170 or Monoply Plus |
1/2" | #97 (1gal/sq) |
C |
Firestone Bldg.Products Co.Carmel, IN. | NC | Firestone | Insulation: Optional Base Sheet: Type G-1, G-2, or G-3 Membrane: Firestone APP 160, 170 or Monoply Plus |
1" | #97 or #97AF (1-1/2gal/sq) #169 (1gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | NC | Firestone | Insulation: UL class Polystyrene
Insulation: min. 1/2 WF |
1/4" | #97 or #97AF (1-1/2gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: UL class any thickness
Barrier Board: Water rest. |
1" | #97 or #97AF (1-1/2gal/sq) #169 |
A |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: UL class any thickness Barrier Board: Regular Wallboard Base Sheet: Type G-1, G-2, or G-3 Membrane: Firestone APP 160, 170 or Monoply Plus |
1" | #97 or #97AF (1-1/2gal/sq) #169 (1gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | NC | Firestone | Insulation: Optional Base Sheet: Type G-1, G-2, or G-3 Membrane: Firestone APP 160, 170 or Monoply Plus |
1" | #97AF (1-1/2gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | NC | Firestone | Insulation: UL class Polystyrene 1" min Insulation: min. 1/2 WF Base Sheet: OFC # 28 Membrane: Firestone APP 160, 170 or Monoply Plus |
1/4" | #97 or #97AF (1-1/2gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: UL class any thickness
Barrier Board: Water rest. Wallboard |
1" | #97 or #97AF (1-1/2gal/sq) #169 (1gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: UL class any thickness
Barrier Board: Regular Wallboard Base Sheet: Type G-1, G-2, or G-3 |
1/2" | #97 or #97AF (1-1/2gal/sq) #169 (1gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | NC | Firestone | Insulation: Optional Base Sheet: Type G-1, G-2, or G-3 Membrane: Firestone APP 160, 170 or Monoply Plus |
1" | #97AF (1-1/2gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | NC | Firestone | Insulation: Optional
Base Sheet: Type G-1, G-2, or G-3 |
1" | #97 or #97AF (1-1/2gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Base Sheet: 2 plys TypeG-2 or SBS Base Ply Sheet: Optional |
1/2" | #97 or #97AF (1-1/2gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: Various Base Sheet: Type G-2 or SBS Base Ply Sheet: Optional |
1/2" | #97 or #97AF (1-1/2gal/sq) |
A |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: Optional Base Sheet: Type G-2 or #28 Membrane: Firestone APP 160, 170 or Monoply Plus |
1/4" | #97 or #97AF (1-1/2gal/sq) |
B |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: UL class Polystyrene 1""min Insulation: min. 1/2"" WF Base Sheet: 1 or more layers #28 Membrane: Firestone APP 160, 170 or Monoply Plus |
1/4" | #97 or #97AF (1-1/2gal/sq) |
B |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Base Sheet: 2plys #28 or Type G-2 Membrane: Firestone APP 160, 170 or Monoply Plus |
1/2" | #97 (1-1/2gal/sq) |
B |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 | Firestone | Insulation: UL class ISO 1""min Base Sheet: 2plys Type G-2 Membrane: Firestone APP 160, 170 or Monoply Plus |
1/4" | #97
(1-1/2gal/sq) |
B |
Firestone Bldg.Products Co.Carmel, IN. | C-15/32 T & G |
Firestone | Base Sheet: Type G-2, MB Base, Z-Base Membrane: Firestone APP 160, 170, 180 |
1/2" | #97 or #97AF (1-1/2gal/sq) |
B |
GAF MaterialsWayne, NJ | NC | GAF | Base Sheet: OptionalMembrane: Ruberoid Mop, Torch, Mop--Plus, Torch Plus | 1/2" | #97 (1 1/2-3gal/sq) | A |
GAF MaterialsWayne, NJ | NC | GAF | Insulation: Optional
Base Sheet: Optional |
1/4" | #97 (1 1/2-3gal/sq) |
A |
GAF MaterialsWayne, NJ | C-15/32 | GAF | Insulation: Various
Base Sheet: Type G-2 or G-3 |
1/2" | #97
(1 1/2-3gal/sq) |
A |
GAF MaterialsWayne, NJ | NC | GAF | Base Sheet: Optional Membrane: Ruberoid Torch or Torch Plus |
1/2" | #97 or #169 (1 1/2-3gal/sq) |
A |
GAF MaterialsWayne, NJ | C-15/32 | GAF | Insulation: Optional Base Sheet: 2 Layers Type G-2 or G-3 Ply Sheet: Optional |
1/2" | #97 (1 1/2-3gal/sq) |
A |
GAF MaterialsWayne, NJ | C-15/32 | GAF | Insulation: Optional
Base Sheet: 2 Layers Type G-2 or G-3 |
1/2" | #97 (1 1/2gal/sq) |
B |
GAF MaterialsWayne, NJ | C-15/32 | GAF | Insulation: Optional
Base Sheet: 1 Layer Type G-2 or G-3 |
1/2" | #97
(1 1/2-3gal/sq) |
B |
GAF MaterialsWayne, NJ | C-15/32 | GAF | Insulation: Various Base Sheet: Type G-2 or G-3 Ply Sheet: Optional Membrane: Ruberoid Mop, Torch, Mop- -Plus, Torch Plus |
2" | #97 (3 gal/sq) |
C |
GAF MaterialsWayne, NJ | NC | GAF | Insulation: Optional ISO Insulation: Various Base Sheet: Optional Membrane: Ruberoid Mop, Torch, Mop- -Plus, Torch Plus |
1/2" | #97 or #169 (1 - 3gal/sq) |
C |
GAF MaterialsWayne, NJ | C-15/32 | GAF | Insulation: Various Base Sheet: Type G-2 or G-3 Membrane: Ruberoid Mop, Mop FR |
2" | #97 (3 gal/sq) # 81 Mod. Bit. |
C |
Globe BuildingMaterials Inc.Whiting, IN. | NC | Globe | Insulation: Perlite, GF, WF any thickness Base Sheet: Type G-2 Membrane: Globe APP-4 |
1/4" | #97 (1-1/2 gal/sq) |
A |
GS Roofing ProductsIrving, TX. | C-15/32 M & R |
GS | Existing System: Class A,B,C (gravel may be removed) Vapor Retarder: Optional Insulation: Optional Base Sheet: Type G-2 Membrane: Flintlastic GTA, GTS or GMS |
1" | #97 (1 1/2gal/sq) |
A |
GS Roofing ProductsIrving, TX. | C-15/32 M & R |
GS | Existing System: Class A,B,C (gravel may be removed) Vapor Retarder: Optional |
3/4" | #97
(1 1/2gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC M & R |
GS | Existing System: Class A,B,C (gravel may be removed) Insulation: Optional Base Sheet: Type G-2 Membrane: Flintlastic FR, Premiun FR-P Flintlastic GMS, GTA, GTS or STA |
3/4" | #97 (1 1/2gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC | GS | Vapor Retarder: Optional Base Sheet: Type G-2 Membrane: Flintlastic STA |
3/4" | #97 (1-1/2gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC | GS | Insulation: Optional Ply Sheet: Type G-2 mech. Attached Membrane: Flintlastic STA, GTA or GTA White or Black Diamond |
1/4" | #97 (1 gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC | GS | Insulation: Various Base Sheet: Type G-2 Membrane: Flintlastic GMS, GMS Premium GMS Black Diamond |
#97 (2-1/2 gal/sq) |
1" | A |
GS Roofing ProductsIrving, TX. | C-15/32 * |
GS | * All joints Blocked W/ 2x4's Insulation: Glass Fiber or Perlite Base Sheet: Type G-2 Membrane: Flintlastic GMS |
1" | #97 (2-1/2 gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC | GS | Insulation: Various Base Sheet: Type G-2Membrane: Flintlastic STA, GTA or GTA White or Black Diamond |
1/2" | #97 (3 gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC | GS | Insulation: Various
Base Sheet: Type G-2 |
1/2" | #97 (2-1/2 gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC | GS | Insulation: Optional
Base Sheet: Type G-2Ply Sheet: Optional |
1/2" | #97 (1-1/2 gal/sq) |
A |
GS Roofing ProductsIrving, TX. | NC | GS | Vapor Retarder: Optional Insulation: Optional Base Sheet: Type G-2 |
1" | #97 (1-1/2 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | C-15/32 | GS | Vapor Retarder: Optional Insulation: Optional Base Sheet: 2 Layers Type G-2 |
1/4" | #97 (1-1/2 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | NC | GS | Insulation: Various Base Sheet: Type G-2 Membrane: Flintlastic GMS, GMS Premium |
2" | #97 (2-1/2 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | C-15/32 * |
GS | * All joints Blocked W/ 2x4's
Insulation: Glass Fiber or Perlite |
1/2" | #97
(1-1/2 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | C-15/32 * |
GS | * All joints Blocked W/ 2x4's Base Sheet: Type G-2 Mech. Fastened Membrane: Flintlastic GTA, STA or GTA White or Black Diamond |
1/4" | #97
(1-1/2 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | C-15/32 * |
GS | * All joints Blocked W/ 2x4's Base Sheet: Type G-2 Nailed Membrane: GMS |
1/2" | #97
(2-1/2 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | C-15/32 * |
GS | * All joints Blocked W/ 2x4's Insulation: Celotex HY-Tec Base Sheet: Type G-2 Membrane: GMS |
1/2" | #97 (2-1/2 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | C-15/32
* |
GS | * All joints Blocked W/ 2x4's Insulation: Celotex HY-Tec Base Sheet: Type G-2 Membrane: Flintlastic GTA, STA or GTA White or Black Diamond |
1/2" | #97 (3 gal/sq) |
B |
GS Roofing ProductsIrving, TX. | C-15/32 | GS | Insulation: Optional Base Sheet: Type G-2Ply Sheet: Optional Membrane: Flintlastic GTA, STA or GTA White or Black Diamond |
1/4" | #97 (1-1/2 gal/sq) |
B |
Herbert Malarkey Rfg.Portland, OR. | NC | Malarkey | Insulation: (Optional) WF, GF, PerliteBase Sheet: Type G-2Membrane: Malarkey 160 APP | 2" | #97 or #97AF(1-1/2 gal/sq) | A |
Herbert Malarkey Rfg.Portland, OR. | NC | Malarkey | Insulation: (Optional) ISO, WF, Etc.(1-1/2 gal/sq)Base Sheet: Type G-2Membrane: Malarkey 160 APP | 1" | #97 or #97AF(1-1/2 gal/sq) | A |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Barrier Board: Water rest. Wallboard Insulation: (Optional) ISO, WF, Etc.Base Sheet: Type G-2Membrane: Malarkey 160 APP | 1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Herbert Malarkey Rfg.Portland, OR. | NC | Malarkey | Base Sheet: Optional Type G-2 Membrane: Malarkey 160 APP |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Base Sheet: 2plies FGP Base Sheet #515 Membrane: Malarkey 160 APP |
1/4" | #97 or #97AF (2 gal/sq) |
A |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Insulation: ISO Base Sheet: FGP Base Sheet #515 Membrane: Malarkey 160 APP |
1/4" | #97 or #97AF (2 gal/sq) |
A |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Insulation: ISO Base Sheet: FGP Base Sheet #515 |
1/2" | #97 or #97AF
(2 gal/sq) |
A |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Insulation: Glass Fiber Base Sheet: Type G-2 Membrane: Malarkey 160 APP |
1/4" | #97 or #97AF (2 gal/sq) |
B |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Base Sheet: Type G-2,GAF,OCF,MAN,TAMKO
Membrane: Malarkey 160 APP |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Insulation: AC Foam IIBase Sheet: FGP Base Sheet #515 Membrane: Malarkey 160 APP |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Insulation: ISO Insulation: WF, GF, Perlite Membrane: Malarkey 160 APP |
1" | #97 or #97AF
(1-1/2 gal/sq) |
B |
Herbert Malarkey Rfg.Portland, OR. | C-15/32 | Malarkey | Insulation: ISO Base Sheet: FGP Base Sheet #515 Membrane: Malarkey 160 APP |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
INTEC/PERMAGLASCorvallis, OR. | NC | US INTEC | Insulation: OptionalPly Sheet: 1+ply Perma Poly Ply Sheet | 1/4" | #97 (1-1/2 gal/sq) | A |
INTEC/PERMAGLASCorvallis, OR. | NC | US INTEC | Insulation: Optional
Base Sheet: Type15, G-2, FlexBase FR60 |
1/4" | #97 (1-1/2 gal/sq) |
A |
INTEC/PERMAGLASCorvallis, OR. | NC | US INTEC | Membrane: Flex Cap APP4S, APP4.5M | 1/4" | #97 (1-2 gal/sq) |
A |
INTEC/PERMAGLASCorvallis, OR. | C-15/32 | US INTEC | Base Sheet: 2 layers Type G-2 Membrane: Flex Cap APP4S, APP4.5M |
1/2" | #97 (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | N/A | Primer: No. 96 Elastomeric PrimerSeam Sealer:(Optional)W/5548 Resat-Mat Base: Elasto-Brite-M Base Finish Coat: Elasto-Brite-M Finish |
UNLIM | #96,1/2 gal/sq
505 S.S 1/8 |
A |
KARNAK Corp.Clark, NJ | NC | N/A | Primer: #447 TD-1 Parts A & B Base: TD-1 #401 Base Coat Finish Coat: TD-1 #403 Finish Coat Aggregate: 35-65 mesh silica sand |
UNLIM | 447,125sqft/gal 401,50 sqft/gal 403,100sqft/gal 8-10 lbs/sq |
A |
KARNAK Corp.Clark, NJ | NC | N/A | Primer: #447 TD-1 Parts A & B
Base: TD-1 #401 Base Coat |
UNLIM | 447,125sqft/gal
401,50 sqft/gal |
A |
KARNAK Corp.Clark, NJ | NC | US INTEC | Insulation: GF, WF, Perlite Base Sheet: Type15, or G-2 Membrane: US INTEC Brai4,B4,BSP-4,SP-4 |
1/4" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | US INTEC | Membrane: US INTEC Brai4,B4 | 1/4" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | US INTEC | Insulation: GF, WF, Perlite
Base Sheet: Type15, or G-2 |
1/4" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | NORDBITUMI | Insulation: GF, WF, Perlite Base Sheet: Type G-2 Membrane: Nord Poly 4B, Nord Poly 5B |
1/2" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | NORDBITUMI | Insulation: GF, WF, Perlite Base Sheet: Type G-2 Membrane: Nordflex S |
1/4" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | Firestone | Insulation: Various Base Sheet: Type G-3 (inverted) |
1" | #169
(1 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | Firestone | Insulation: Various Base Sheet: Type G-1, G-2, G-3 Membrane: Firestone APP-160, APP-170 |
1" | #97 or #169 (1 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | Pro. Bldg. Products |
Insulation: Various Base Sheet: Type G-1, G-2 Membrane: Derbigum |
1/2" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | TAMKO | Insulation: ISO 1.5 TO 2.5 IN.
Base Sheet: 3 lAYERS Type G-1 |
1/4" | #97 (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | N/A | Insulation: Various Ply Sheet: 3 + Layers Type G-1or G-2 |
1" | #220AF (3 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | N/A | Insulation: GF, WF, Perlite Ply Sheet: 3 + Layers Type G-1or G-2 |
3" | #220AF
(3 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | TAMKO | Base Sheet: 1 or more Layer Type G-1 Base Sheet: Optional Membrane: 1 layer Awaplan Granule |
1/4" | #81AF@(3gal/sq) #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | TypeG1orG2 | Insulation: Composite any thickness M/A Base/Ply Sheet: 1 or more G-1,G-2 mopped Followed by Glaze coat |
1/4" | #97 or #97AF (1-1/2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC | TypeG1orG2 | Insulation: GF 3/4""min. Mech. Attached
Base/Ply Sheet: 4 plies G-1, G-2 Mopped |
1" | #97AF (1-1/2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | C-15/32 | NordBitumi | Base Sheet: Type G-2 Membrane: Nord Poly 4B |
1/4" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | C-15/32 | Firestone | Insulation: GF, WF, Perlite, ISO Base Sheet: Type G-2 Membrane: Firestone APP-160, APP-170 or Monoply Plus |
1/4" | #97 or #97AF
(1 gal/sq) |
A |
KARNAK Corp.Clark, NJ | C-15/32 | ProBldProd | Insulation: 1/2"" Gyp Board Base Sheet: Type G-1 Membrane: Derbigum |
1/2" | #97 or #97AF (1-2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | C-15/32 | TAMKO | Insulation: GF, WF, Perlite
Base Sheet: Optional can be adhered W/ |
1/4" | #81AF @ (1-1 1/2gal/sq) |
B |
KARNAK Corp.Clark, NJ | C-15/32
M & R |
Firestone | Existing System: Class A covered W/ Membrane: Firestone APP-160, APP-170 or Monoply Plus |
1/2" | #97 or #97AF (1 gal/sq) |
A |
KARNAK Corp.Clark, NJ | C-15/32
M & R |
Firestone | Existing System: Class A,B,C covered W/ Base Sheet: Type G-3 (inverted) Membrane: Firestone APP-160, APP-170 or Monoply Plus |
1" | #97 or #97AF (1 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC M & R |
Firestone | Existing System: BUR any Class A, B, C Insulation: ISO,Urethane,GF, WF, Perlite Base Sheet: Type G-1,G-2,G-3 1 or more layers optional Membrane: |
1" | #97 or #97AF (1 gal/sq) |
A |
KARNAK Corp.Clark, NJ | C-15/32 | N/A | Existing System: BUR Any Class A,B,C Base Coat: #16AF or #78AF C.P.C. Ply Coat: 1 or more layers Polyester Mat Top Coat: #16AF or #78AF C.P.C. |
1/2" | #16AF or #78AF (2-1/2 gal/sq) 4 gal/sq/Gravel |
A |
KARNAK Corp.Clark, NJ | NC M & R |
N/A | Existing System: BUR Any Class A,B,C Base Coat: #16AF or #78AF C.P.C. Ply Coat: 1 or more layers Polyester Mat Top Coat: #16AF or #78AF C.P.C. |
2" | #16AF or #78AF
(2-1/2 gal/sq) |
A |
KARNAK Corp.Clark, NJ | NC
M & R |
N/A | Existing System: BUR Class A,B,C Base Coat: #220AF FiberedAsphaltEmulsion Ply Coat: 1 or more layers Polyester Mat Top Coat: #220AF FiberedAsphaltEmulsion |
3" | #220AF (2 gal/sq) (3 gal/sq) |
A |
KARNAK Corp.Clark, NJ | C-15/32 M & R |
Firestone | Existing System: Class B covered W/ Membrane: Firestone APP-160, APP-170 or Monoply Plus |
1/2" | #97 or #97AF (1 gal/sq) |
B |
KARNAK Corp.Clark, NJ | C-15/32 M & R |
Firestone | Existing System: Class C covered W/
Membrane: Firestone APP-160, APP-170 or Monoply Plus |
1/2" | #97 or #97AF (1 gal/sq) |
C |
Koppers Indust.Pittsburgh, PA. | NC | Koppers | Insulation: (Optional) GF, WF, perlite
Base Sheet: Type G-2 |
2" | #97 or #97AF (1 to 2 gal/sq) |
A |
Koppers Indust.Pittsburgh, PA. | NC | Koppers | Insulation: GF, WF, perlite 1-1/2"" max. Base Sheet: Type G-2 Membrane: 2041-M, 2041-S, 2045-M |
1/4" | #97 or #97AF (1 to 2 gal/sq) |
A |
Koppers Indust.Pittsburgh, PA. | NC | Koppers | Base Sheet: (Optional) Type G-2 Membrane: 2040-S, 2050-S |
1" | #97 or #97AF
(1 to 2 gal/sq) |
A |
Koppers Indust.Pittsburgh, PA. | C-15/32 | Koppers | Insulation: GF 1-1/2 Base Sheet: Type G-2 Membrane: 2040-S, 2050-S |
1/4" | #97 or #97AF (2 gal/sq) |
B |
MB Technology Corp.Fresno,CA. |
NC | Fastorch | Insulation: (Optional) WF, GF, Perlite Base Sheet: (Optional) Type G-1, G-2 Membrane: FASTORCH SBS 160 mil, 160 mil granule, or SUPERFLEX 160 mil granule |
1/2" | #97 (1-1/2 gal/sq) |
A |
MB Technology Corp.Fresno,CA. | NC | Fastorch | Insulation: GF, Perlite 3/4"" to 1-1/2" Base Sheet: 1 or more layers TypeG-1,G-2 Membrane: FASTORCH SBS 160 mil, 160 mil granule, or SUPERFLEX 160 mil granule |
1/4" | #97
(1-1/2 gal/sq) |
A |
Nord Bitumi US Macon, GA. | NC | NORD | Insulation: (Optional) WF, GF, Perlite Base Sheet: Type G-2 Membrane: Nord Poly NP-4B,4M,5B,Nord-200 |
2" | #97 or #97AF
(1 to 2 gal/sq) |
A |
Nord Bitumi US Macon, GA. |
NC | NORD | Insulation: (Optional) WF,GF,Perlite,ISO Base Sheet: Type G-2 Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, Ultra S, M, 170 |
1" | #97 or #97AF | A |
Nord Bitumi US Macon, GA. |
C-15/32 | NORD | Barrier Board: Water Resist. 1/2 Gypsum
Insulation: (Optional) WF,GF,Perlite,ISO |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Nord Bitumi US Macon, GA. |
NC | NORD | Base Sheet: Type G-2
Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Nord Bitumi US Macon, GA. |
C-15/32 | NORD | Base Sheet: 2 plies Type G-2 Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, 170, Ultra S, |
1/4" | #97 or #97AF (2 gal/sq) |
A |
Nord Bitumi US Macon, GA. |
C-15/32 | NORD | Insulation: ISO, ISO/Perlite composite Base Sheet: Type G-2 Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, 170, Ultra S, |
1/2" | #97 or #97AF (2 gal/sq) |
A |
Nord Bitumi US Macon, GA. |
C-15/32 | NORD | Insulation: GF 1-1/2" Base Sheet: Type G-2 Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, M, 170, Ultra M |
1/4" | #97 or #97AF
(2 gal/sq) |
B |
Nord BitumiUS Macon, GA. |
C-15/32 | NORD | Base Sheet: 1 or more plies Type G-2 Membrane: Nord Poly NP-4B,4M,5B,Nord-200 EM-4000, Nordflex S, M, or Ultra |
1/2" | #97 or #97AF (1-1/2-2gal/sq) |
B |
Nord Bitumi US Macon, GA. |
C-15/32 | NORD | Insulation: ACFoam II 1.2""min. Base Sheet: 1 or more plies Type G-2 Membrane: Nord Poly NP-4B, 4M, Nord-200 EM-4000, Nordflex |
1/2" | #97 or #97AF (1-1/2-2gal/sq) |
B |
Nord Bitumi US Macon, GA. |
C-15/32 | NORD | Insulation: ISO. 1.2""min. Insulation: WF, GF, Perlite, 1/2" Membrane: Nord Poly NP-4B, 4M, Nord-200 EM-4000, Nordflex S, M, or Ultra |
1" | #97 or #97AF (1-1/2-2gal/sq) |
B |
Nord Bitumi US Macon, GA. |
C-15/32 | NORD | Insulation: ISO, ISO/Perlite composite Base Sheet: Type G-2 Membrane: Nord Poly NP-4B,5B,4M,Nord-200 EM-4000, Nordflex S, M, 170, or Ultra M |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
Nord Bitumi US Macon, GA. |
C-15/32 M & R |
NORD | Existing System: Class A, B, C (Gravel may be removed) Insulation: (Optional) Various |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
Nord Bitumi US Macon, GA. |
C-15/32 M & R |
NORD | Existing System: Class A, B smooth BUR (Gravel may be removed) Insulation: (Optional) Various Base Sheet: 1 or more pliesType G-2 or Multiple layers Type G-1 Membrane: Nord Poly NP-4B,5B,4M,Nord-200 EM-4000, Nordflex S, M, 170, or Ultra M |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
Performance Rfg.Systems, Inc. | NC | Permax | Insulation: WF, GF, Perlite, 1/2"" Max. Base Sheet: Type G-1,G-2,15 or 30 sheet Membrane: Permax A-Economy, A-Special, A-Xtra, {(A-Special & A-Xtra) Mineral} |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
A |
Performance Rfg.Systems, Inc. | NC | Permax | Insulation: WF, GF, Perlite, ISO, Compos Base Sheet: Type G-2 Membrane: Permax A-Economy, A-Special, A-Xtra, {(A-Special & A-Xtra) Mineral}, Permax B-Economy, B-Special, B-Xtra, B-Xtra 250 |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Performance Rfg.Systems, Inc. | C-15/32 | Permax | Base Sheet: 2plies Type G-2 or 1ply G-2 Membrane: Permax A-Economy, A-Special, A-Xtra, {(A-Special & A-Xtra) Mineral}, Permax B-Economy, B-Special, B-Xtra, B-Xtra 250 |
1/4" | #97 or #97AF
( 2 gal/sq ) |
A |
Performance Rfg.Systems, Inc. | C-15/32 | Permax | Insulation: ISO, ISO/Composit Base Sheet: 2plies Type G-2 or 1ply G-2 Membrane: Permax A-Economy, A-Special, A-Xtra, {(A-Special & A-Xtra) Mineral}, Permax B-Economy, B-Special, B-Xtra, B-Xtra 250 |
1/2" | #97 or #97AF
( 2 gal/sq ) |
A |
Performance Rfg.Systems, Inc. | NC | Derbigum | Base Sheet: (Optional)1/moreType G-1,G-2 Insulation: (Optional) GF, Per.,ISO,Comp Ply Sheet:2 or more Type G-1 or G-2 Membrane: Derbigum |
1/4" | #97 or #97AF
(1-1/2 gal/sq) |
A |
Performance Rfg.Systems, Inc. | C-15/32 | Derbigum | Base Sheet: (Optional)1/moreType G-1,G-2 Insulation: (Optional) GF, Per.,ISO,Comp Ply Sheet:2 or more Type G-1 or G-2 Membrane: Derbigum |
1/4" | #97 or #97AF
(1-1/2 gal/sq) |
A |
Performance Rfg.Systems, Inc. | C-15/32 | Permax | Insulation: GF 1-1/2" Base Sheet: 1ply Type G-2 Membrane: Permax A-Economy, A-Special, A-Xtra, {(A-Special & A-Xtra) Mineral}, |
1/4" | #97 or #97AF
(1 to 2 gal/sq) |
B |
Performance Rfg.Systems, Inc. | C-15/32 | Derbigum | Insulation: GYP 1/2", GF 1-1/2" min. Base Sheet: 1+ ply Type G-1 or G-2 Membrane: Derbigum |
1/2" | #97 (1-1/2 gal/sq) |
B |
Performance Rfg.Systems, Inc. | C-15/32 | Derbigum | Base Sheet: (Optional)1/moreType G-1,G-2
Insulation: (Optional) GF, Per.,ISO,Comp |
1/4" | #97 (1-1/2 gal/sq) |
B |
Polara Rfg.Sys.Durham, N.C. | NC | Polara | Insulation: GF, Per., ISO, ISO/Comp Base Sheet: Type G-2 Membrane: Polara MB Cap Sheet |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Polara Rfg.Sys.Durham, N.C. | C-15/32 | Polara | Base Sheet: 2 plies G-1 or 1 ply G-2
Membrane: Polara MB Cap Sheet |
1/4" | #97 or #97AF (2 gal/sq) |
A |
Polara Rfg.Sys.Durham, N.C. | C-15/32 | Polara | Insulation: ISO, ISO/Comp Base Sheet: 2 plies G-1 or 1 ply G-2 Membrane: Polara MB Cap Sheet |
1/2" | #97 or #97AF (2 gal/sq) | A |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
NC | Coverply | Insulation: (Optional) WF, GF, PerliteBase Sheet: Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral |
2" | #97 or #97AF (1 to 2 gal/sq) |
A |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico | NC | Coverply | Insulation: (Optional) WF, GF, Perlite ISO, ISO/Perlite Composite Base Sheet: Type G-2 |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Barrier Board: Water Resist. 1/2"" GYP Insulation: (Optional) WF, GF, Perlite ISO, ISO/Perlite Composite |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
NC | Coverply | Base Sheet: (Optional) Type G-2
Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Base Sheet: 2 Plies Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, SBS 3mm Smooth, 4mm Smooth |
1/4" | #97 or #97AF (2 gal/sq) |
A |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Insulation: ISO, ISO/Perlite Comp. 2""min Base Sheet: Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, SBS 3mm Smooth, 4mm Smooth |
1/2" | #97 or #97AF (2 gal/sq) |
A |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Insulation: GF 1-1/2" Base Sheet: Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, SBS 3mm Smooth, 4mm Smooth |
1/4" | #97 or #97AF
(2 gal/sq) |
|
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Base Sheet: 1 or more plies Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, SBS 3mm Smooth, 4mm Smooth |
1/2" | #97 or #97AF (1-1/2-2gal/sq) |
B |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Insulation: AC Foam II 1.2"" min Base Sheet: 1 or more plies Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, |
1/2" | #97 or #97AF (1-1/2-2gal/sq) |
B |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Insulation: ISO 1.2" Insulation: WF, GF, Perlite 1/2"" min Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, SBS 3mm Smooth, 4mm Smooth |
1" | #97 or #97AF (1-1/2-2gal/sq) |
B |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 | Coverply | Insulation: ISO 1.2" Base Sheet: Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, SBS 3mm Smooth, 4mm Smooth |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32
M & R |
Coverply | Existing Roof System: Class A,B,C Insulation: (Optional)ISO,Comp,GF,WF,PER Insulation: "Nord Board" (Gravel may be removed) |
1/2" | #97 or #97AF (1-1/2 gal/sq) |
B |
Proteccion Ant-icorrosiva De Cuautitlan S A DE C V EDO DE Mexico Mexico |
C-15/32 M & R |
Coverply | Existing Roof System:Class A,B SmoothBUR Insulation: (Optional)ISO,Comp,GF,WF,PER Base Sheet: 1 or more plies Type G-2 Membrane: Coverply APP 3mm Smooth, 4mm Smooth, 4.5mm Mineral, SBS 3mm Smooth, 4mm Smooth |
1/2" | #97 or #97AF
(1-1/2 gal/sq) |
A |
SchullerInternational(Form.Manville) Littleton, CO. | NC | Schuller | Base Sheet: PermaPly #28, GlasBase,GlasPly IV, Premier, PermaPly R Ply Sheet: GlasPly IV,Premier,PermaPly R | 1/4" | #97 or #97AF(1-1/2 gal/sq) | A |
SchullerInternational(Form.Manville) Littleton, CO. | NC | Schuller | Base Sheet: (Optional) PermaPly #28, GlasBase,GlasPly IV, Premier, PermaPly R Insulation: (Optional) Fesco, Fesco-Foam Fes-Core, Ultra-Gard, FiberGlass Ply Sheet: 2 or More Plies GlasPly IV, GlasPly Premier, PermaPly R |
1/4" | #97 or #97AF (1-1/2 gal/sq) |
|
Simon Rfg. & S//MCorp.Youngstown, OH. | C-15/32 | Simon | Barrier Board: Water Resist. 1/2" GYP. Insulation: (Optional)ISO, IOS/Comp., Perlite, GF, WF Membrane: SR-Flex M Premium |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
Simon Rfg. & S//MCorp.Youngstown, OH. | C-15/32 | Simon | Insulation: GF 1-1/2" Base Sheet: Type G-2 Membrane: SR-Flex M Premium |
1/4" | #97 or #97AF
(2 gal/sq) |
B |
Simon Rfg. & S//MCorp.Youngstown, OH. | C-15/32 | Simon | Base Sheet: 1 or more plies Type G-2
Membrane: 1 or more plies SR-Flex M Premium |
1/2" | #97 or #97AF (1-1/2 to 2gal/sq) |
B |
Simon Rfg. & S//MCorp.Youngstown, OH. | C-15/32 | NORD | Insulation: AC Foam II 1.2" Base Sheet: 1 or more plies Type G-2 Membrane: 1 or more plies Nord 4B, 4M, 200, or EM-4000 APP |
1/2" | #97 or #97AF (1-1/2 to 2gal/sq) |
B |
Simon Rfg. & S//MCorp.Youngstown, OH. | C-15/32 | NORD | Insulation: ISO 1.2" Insulation: WF, GF, Perlite 1/2"Membrane: 1 or more plies Nord 4B, 4M, 200, or EM-4000 APP, SR Flex M Premium |
1" | #97 or #97AF (1-1/2 to 2gal/sq) |
B |
Soprema Inc.Quebec, Canada | NC M & R |
Soprema | Existing Roof System: Class A,B,C (Gravel may be removed) Insulation: WF ""Structodeck-FS" |
1-1/2" | #97 (1-1/2 gal/sq) |
A |
Soprema Inc.Quebec, Canada | NC | Soprema | Insulation: (Optional) ISO,Perlite,WF,GF Base Sheet: Type G-2, Sopraglass 40, 100 Membrane: Sopralene 180, 250 Sanded |
1" | #97 (1-1/2 gal/sq) |
A |
Soprema Inc.Quebec, Canada | C-15/32 | Soprema | Insulation: (Optional) Perlite, WF, GF Base Sheet: Type G-2, Sopraglass 40, 100 Ply Sheet: Elastophene Sanded, 180Sanded Elastophene PS, 180 PS |
1-1/2" | #97 (1-1/2 gal/sq) |
A |
Soprema Inc.Quebec, Canada | C-15/32 | Soprema | Insulation: ISO 1.2"" min. Base Sheet: Type G-2, Sopraglass 40, 100 Ply Sheet: Elastophene Sanded, 180Sanded |
1-1/2" | #97 (1-1/2 gal/sq) |
A |
Soprema Inc.Quebec, Canada | NC | Soprema | Insulation: (Optional) Perlite, WF, GFBase Sheet: Type G-2, Sopraglass 40, 100 Ply Sheet: Elastophene Sanded, 180Sanded Elastophene PS, 180 PS Membrane: Sopralene 180, 250 Sanded |
1-1/2" | #97 (1-1/2 gal/sq) |
A |
Soprema Inc.Quebec, Canada | NC | Soprema | Insulation: (Optional) Perlite, WF, GF Base Sheet: (Optional)Type G-2, Sopraglass 100 Base/Ply Sheet: Elastophene Sanded, 180 Sanded, Elastophene |
1" | #97 (1-1/2 gal/sq) |
A |
TAMKO Rfg, Pords.Joplin, MO. | NC | TAMKO | Base Sheet: 1 or more layers Type G-2, Base Sheet: (Optional) Type 15 organic or 43lb Base Membrane: Awaplan granule reg. or APP |
1/4" | #97 or #97AF (1-1/2 gal/sq) |
A |
TAMKO Rfg, Pords.Joplin, MO. | C-15/32
Joints |
TAMKO | Base Sheet: (Optional) Type 15 organic or 43lb Base Insulation: GF, WF Perlite, Apache/Celotec ISO Base Sheet: Type G-2, Membrane: Awaplan Premium, 170 |
1/4" | #97 or #97AF (1-1/2 gal/sq) |
A |
Texas RefineryCorp.Ft Worth, TX. | NC | Mighty- -plate |
Insulation: Perlite, WF, GF
Base Sheet: Type G-2 |
1" | #97 (1-1/2 gal/sq) |
A |
Thunderhawk Mfg.Monroe,GA.Providence, RI | NC | Unknown | Insulation: (Optional) Perlite, WF, GF Base Sheet: Type 15 organic or Type G-2 Membrane: TP-4 or TP-4G |
1/4" | #97 (1 to 2 gal/sq) |
A |
Thunderhawk Mfg.Monroe,GA.Providence, RI | NC | Unknown | Membrane: TP-4 or TP-4G | 1/4" | #97 (1 to 2 gal/sq) |
A |
Thunderhawk Mfg.Monroe,GA.Providence, RI | NC | Unknown | Base Sheet: 2 Layers Type G-2 Membrane: TP-4 or TP-4G |
1/2" | #97
(1-1/2 gal/sq) |
B |
Thunderhawk Mfg.Monroe,GA.Providence, RI | NC | Unknown | Base Sheet: Type G-2 Membrane: TP-4 |
1/4" | #97 (1-1/2-2gal/sq) |
B |
TRI-PLY Inc.Clawson, MI. | NC | TRI-PLY | Insulation: (Optional) Perlite, WF, GF Base Sheet: Type 15 organic or Type G-2 Membrane: TP-4 or TP-4G |
1/4" | #97 (1 to 2 gal/sq) |
A |
TRI-PLY Inc.Clawson, MI. | NC | TRI-PLY | Membrane: TP-4 or TP-4G | 1/4" | #97 (1 to 2 gal/sq) |
A |
TRI-PLY Inc.Clawson, MI. | C-15/32 | TRI-PLY | Base Sheet: 2 Layers Type G-2 Membrane: TP-4 or TP-4G |
1/2" | #97 (1-1/2 gal/sq) |
B |
TRI-PLY Inc.Clawson, MI. | C-15/32 | TRI-PLY | Base Sheet: Type G-2
Membrane: TP-4 |
1/4" | #97 (1-1/2-2gal/sq) |
B |
TRI-PLY Inc.Clawson, MI. | NC | TRI-PLY | Insulation: Perlite, WF, GF 2"" max. Base Sheet: Type 15 organic or Type G-2 Membrane: TP-4 |
1/4" | #97 (1 to 2 gal/sq) |
C |
TRI-PLY Inc.Clawson, MI. | C-15/32 M & R |
TRI-PLY | Existing Roof System: Class A Base Sheet: Type G-2 Membrane: TP-4 or TP-4G |
1/2" | #97 (1-1/2-2gal/sq) |
A |
U S INTECPort Arthur, TX | NC | BRAI | Insulation: (Optional) ISO,Perlite,WF,GF Base Sheet: Type 15 organic or Type G-2 Membrane: BRAI 4, SP-4, GBSP-4 |
1/4" | #97 or #97AF
(1 to 2 gal/sq) |
A |
U S INTECPort Arthur, TX | C-15/32 | BRAI | Insulation: 2 Layers GF 1"" each Base Sheet: Type G-2 Membrane: BRAI 4, SP-4, GBSP-4 |
1/4" | #97 (1 to 2 gal/sq) |
A |
U S INTECPort Arthur, TX | NC | BRAI | Membrane: BRAI 4, SP-4, GBSP-4 | 1/4" | #97 (1 to 2 gal/sq) |
A |
U S INTECPort Arthur, TX | NC M & R |
BRAI | Existing Roof System: Class A, B or C (Gravel may be removed) Insulation: (Optional) ISO, Perlite, WF |
1/4" | #97 (1-1/2 gal/sq) |
A |
U S INTECPort Arthur, TX | C-15/32 M & R |
BRAI | Existing Roof System: Class A (Gravel may be removed) Base Sheet: Type G-2 Membrane: BRAI SP-4, GBSP-4 |
1/2" | #97 (1-1/2 gal/sq) |
A |
U S INTECPort Arthur, TX | C-15/32
M & R |
BRAI | Existing Roof System:ClassA,B covered W/ Base Sheet: Celotex Celo-Glas Cap Sheet (Granule side down) Membrane: BRAI 4, SP-4, GBSP-4 |
1/2" | #97 (1 to 2 gal/sq) |
B |
U S Single PlyFT Worth, TX. | NC | US Single Ply | Insulation: Perlite, WF, GF Base Sheet: Type G-2 Membrane: U.S. Single Ply Mod. Bit. Mem. |
1/4" | #97 (1-1/2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
NC | Hickman | Insulation: Perlite, WF, GF Base Sheet: Type G-2 Membrane: Pika-Ply SA-4 |
1/2" | #97 (1 to 2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Base Sheet: 2 Plies Type G-2 Membrane: Pika-Ply SA-4 Membrane: Pika-Ply SA-4 |
1/4" | #97
(1 to 2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
NC | Hickman | Insulation: (Optional) Perlite, WF, GF, ISO, ISO/Perlite Composite Base Sheet: Type G-2 Membrane: Pika-Ply SS-4, SS-3P |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Barrier Board: Water Resist. GYP 1/2"
Insulation: (Optional) Perlite, WF, GF, |
1" | #97 or #97AF
(1-1/2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
NC | Hickman | Base Sheet: (Optional) Type G-2 Membrane: Pika-Ply SS-4, SS-3P |
1" | #97 or #97AF (1-1/2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Base Sheet: 2 Plies Type G-2 Membrane: Pika-Ply SS-4, SS-3P |
1/4" | #97 or #97AF (2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Insulation: ISO, ISO/Perlite Composite Base Sheet: Type G-2 Membrane: Pika-Ply SS-4, MS-4, SS-3P |
1/2" | #97 or #97AF (2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
NC | Hickman | Insulation: 1/2""Perlite Mop Type3 Aspht. Base Sheet: 2 or more Type G-1 mopperd Membrane: Pika-Ply 808 mopped |
1/4" | #97 or #97AF
(2 gal/sq) |
A |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Insulation: Glas Fiber 1/2" Base Sheet: Type G-2 Membrane: Pika-Ply SA-4 |
1/4" | #97 (2 gal/sq) |
B |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Insulation: Glas Fiber 1/2"
Base Sheet: Type G-2 |
1/4" | #97 or #97AF (2 gal/sq) |
B |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Insulation: AC Foam II 1.2" Base Sheet: 1 or mor plies Type G-2 Membrane: Pika-Ply SS-4, SS-3P |
1/2" | #97 or #97AF (1-1/2-2gal/sq) |
B |
W P Hickman Systems Inc. Solon, OH. |
C-15/32 | Hickman | Insulation: ISO 1.2" Insulation: WF, GF, Perlite 1/2" min Membrane: Pika-Ply SS-4, MS-4 |
1" | #97 or #97AF (1-1/2-2gal/sq) |
B |